Medical equipment & consumables · Dubai, UAETrade supply across the UAE, GCC and Africa
+971 58 525 3411WhatsApp Us
Talk to our team
Dräger VentStar Helix Dual Heated (N) Plus Neonatal CircuitDräger logoMasks & Circuits
Masks & Circuits · Dräger

Dräger VentStar Helix Dual Heated (N) Plus Neonatal Circuit

SKU MP02650Respiratory CarePricing via RFQ

A disposable dual-heated neonatal breathing circuit with heating in both limbs, for Dräger Babylog and Evita ventilators in neonatal intensive care.

Pricing provided via RFQ
Volume discounts available
Bulk & trade orders welcome
Supplied across the UAE, GCC & Africa
Arabic & English-speaking team
Itemised quotation within 24 hours

The Dräger VentStar Helix dual heated (N) Plus is a single-use neonatal breathing circuit with heating wires in both the inspiratory and the expiratory limb. Heating both limbs addresses condensate along the whole gas path, rather than only between the humidifier and the patient as an inspiratory-heated circuit does.

The circuit is built to neonatal and paediatric dimensions so its internal volume stays proportionate to small tidal volumes, and it is discarded after the patient episode. The circuit is specified for neonatal and paediatric patients in neonatal intensive care. It is listed against the Dräger Babylog ventilator family, covering Babylog 8000 Plus, Babylog VN500, Babylog VN600 and Babylog VN800, and against the Evita V300, Evita V500, Evita V600 and Evita V800.

It differs from the single-heated VentStar Helix heated (N) Plus in the number of heated limbs, and units generally choose between the two according to their humidification protocol. Units running both Babylog and Evita platforms can hold this single line across the two, which keeps the neonatal circuit stock list short.

This item is ordered under Dräger part number MP02650 with GTIN 4048675396109 and is supplied as a disposable consumable. The dual-heated and single-heated neonatal circuits carry similar names, so the part number should appear on the purchase order to secure the correct configuration. HumaNova supplies Dräger respiratory consumables to medical supply distributors and resellers across the UAE, the wider GCC and Africa.

Pricing is by request for quotation. Send us the part number, the quantity and the ventilator models in your unit, and we will confirm the configuration and return a written quotation. The neonatal humidifier chambers and heater adapters used with this circuit can be added to the same quotation where a full humidification set is being ordered.

WhatsApp us