Medical equipment & consumables · Dubai, UAEDelivery across the UAE and GCC
+971 58 525 3411WhatsApp Us
Talk to our team
Dräger Temperature Probe and Flow Sensor 900 MR 868 for MR850, 1.1 mDräger logoMasks & Circuits
Masks & Circuits · Dräger

Dräger Temperature Probe and Flow Sensor 900 MR 868 for MR850, 1.1 m

SKU 8414989Respiratory CarePricing via RFQ

Combined temperature probe and flow sensor of 1.1 m for the Fisher & Paykel MR850 humidifier, for use with all breathing circuit types.

Pricing provided via RFQ
Volume discounts available
Documentation on request
Supplied across the UAE, GCC & Africa
Installation & training available
Itemised quotation within 24 hours

1 metre probe carries the temperature sensing that a Fisher & Paykel MR850 humidifier uses to control chamber heating and heater wire output. It is specified for all breathing circuit types rather than a single configuration, which makes it the general-purpose probe length in the MR850 range. Correct probe length matters, because the probe sets where the sensing points sit along the circuit relative to the chamber outlet and the patient connection.

It is used in intensive care and neonatal intensive care wherever active humidification is applied during ventilation, across adult, paediatric and neonatal circuits. The probe is listed against the Dräger Savina, Savina 300, Savina 300 Classic, Savina 300 NIV and Savina 300 Select ventilators, the Evita 2 dura, Evita 4, Evita XL, Evita V300, Evita V500, Evita V600 and Evita V800, the Babylog 8000 plus, Babylog VN500 and Babylog VN800, and Pulmovista 500.

It remains with the humidifier when the circuit is changed. The probe is supplied as a single part under order code 8414989, GTIN 9420012401304, manufactured in New Zealand. HumaNova supplies Dräger respiratory accessories and humidification components to hospitals, clinics and laboratories across the United Arab Emirates and the GCC.

5 m variants serve different circuit configurations. Pricing is by request for quotation; send your quantity and delivery location to HumaNova for a written quotation. Where several humidifiers are being equipped, list the probe length required against each of them.

Related masks & circuits

Dräger BabyFlow Nasal Mask Size 4, Disposable, Box of 10

Dräger BabyFlow Nasal Mask Size 4, Disposable, Box of 10

Dräger
Dräger ClassicStar plus NIV Nasal Mask, Non-Vented, Size XL

Dräger ClassicStar plus NIV Nasal Mask, Non-Vented, Size XL

Dräger
Dräger ClassicStar plus NIV Oronasal Mask with AAV, Size XL

Dräger ClassicStar plus NIV Oronasal Mask with AAV, Size XL

Dräger
Dräger ComfortStar Anaesthesia Mask, Strawberry, Size 4, Box of 20

Dräger ComfortStar Anaesthesia Mask, Strawberry, Size 4, Box of 20

Dräger
Dräger Draw Wire for Hose Heater, 1.5 m, Reusable Breathing Circuits

Dräger Draw Wire for Hose Heater, 1.5 m, Reusable Breathing Circuits

Dräger
WhatsApp us
Dräger Temperature Probe 900 MR 868 for MR850, 1.1 m | HumaNova