Medical equipment & consumables · Dubai, UAEDelivery across the UAE and GCC
+971 58 525 3411WhatsApp Us
Talk to our team
Dräger Temperature Probe 900 MR 863 for MR850, HFO Circuits, 0.7 mDräger logoMasks & Circuits
Masks & Circuits · Dräger

Dräger Temperature Probe 900 MR 863 for MR850, HFO Circuits, 0.7 m

SKU 8418507Respiratory CarePricing via RFQ

Temperature probe of 0.7 m for the Fisher & Paykel MR850 humidifier, specified for high-frequency oscillatory ventilation breathing circuits.

Pricing provided via RFQ
Volume discounts available
Documentation on request
Supplied across the UAE, GCC & Africa
Installation & training available
Itemised quotation within 24 hours

This temperature probe reports circuit gas temperature back to a Fisher & Paykel MR850 humidifier so the controller can regulate chamber and heater wire output. 7 metres and is the variant specified for high-frequency oscillatory ventilation circuits, which are shorter and configured differently from conventional circuits.

Using the correct probe length matters, because the probe positions the sensing points at defined locations along the circuit. It is used in intensive care and neonatal intensive care during high-frequency oscillatory ventilation with active humidification, across neonatal, paediatric and adult HFO circuits.

The probe is listed against the Dräger Babylog 8000 plus, Babylog VN500 and Babylog VN800 neonatal ventilators. It is a reusable component that stays with the humidifier rather than being discarded with the circuit, and departments generally hold spares because the cable and connector are subject to repeated handling.

The probe is supplied as a single part under order code 8418507, GTIN 9420012401298, manufactured in New Zealand. HumaNova supplies Dräger respiratory accessories and humidification components to hospitals, clinics and laboratories across the United Arab Emirates and the GCC. 5 m variants are not interchangeable.

Pricing is by request for quotation. Send your quantity and delivery location to HumaNova for a written quotation. Where several humidifiers are being equipped, list the probe length required against each one so the quantity and variant are both confirmed before the order is raised.

Related masks & circuits

Dräger BabyFlow Nasal Mask Size 4, Disposable, Box of 10

Dräger BabyFlow Nasal Mask Size 4, Disposable, Box of 10

Dräger
Dräger ClassicStar plus NIV Nasal Mask, Non-Vented, Size XL

Dräger ClassicStar plus NIV Nasal Mask, Non-Vented, Size XL

Dräger
Dräger ClassicStar plus NIV Oronasal Mask with AAV, Size XL

Dräger ClassicStar plus NIV Oronasal Mask with AAV, Size XL

Dräger
Dräger ComfortStar Anaesthesia Mask, Strawberry, Size 4, Box of 20

Dräger ComfortStar Anaesthesia Mask, Strawberry, Size 4, Box of 20

Dräger
Dräger Draw Wire for Hose Heater, 1.5 m, Reusable Breathing Circuits

Dräger Draw Wire for Hose Heater, 1.5 m, Reusable Breathing Circuits

Dräger
WhatsApp us
Dräger Temperature Probe 900 MR 863, HFO, 0.7 m | HumaNova