Medical equipment & consumables · Dubai, UAEDelivery across the UAE and GCC
+971 58 525 3411WhatsApp Us
Talk to our team
Dräger TOF+ Reusable Eyebrow Sensor (Software 1.8 and Later)Dräger logoCables, Sensors & Cuffs
Cables, Sensors & Cuffs · Dräger

Dräger TOF+ Reusable Eyebrow Sensor (Software 1.8 and Later)

SKU MS40321Parts & AccessoriesPricing via RFQ

A reusable eyebrow sensor for Dräger TOFscan monitors on software 1.8 and later, used when the hands and feet are unavailable for neuromuscular monitoring.

Pricing provided via RFQ
Volume discounts available
Documentation on request
Supplied across the UAE, GCC & Africa
Installation & training available
Itemised quotation within 24 hours

8 or later. It is positioned at the brow so that the facial nerve is stimulated and the response of the corrugator supercilii muscle is captured by the sensor's acceleromyography element. Placement at this site gives a reading from a facial muscle group rather than from the limbs, and it is selected when the usual peripheral sites cannot be used.

The eyebrow sensor is used in operating rooms during general anaesthesia where both hands and feet are inaccessible — under drapes, in use for vascular access, or within the surgical field. It is specified for adult and paediatric patients and forms part of the TOF+ sensor range for TOFscan handhelds.

7 or earlier take the earlier TOFscan sensor range, so the software revision should be confirmed before the order is placed. The sensor is supplied individually under part number MS40321, manufactured in France and identified by GTIN 3665023000504. HumaNova supplies this item to hospitals, clinics and laboratories across the United Arab Emirates and the wider GCC.

Orders are raised against the Dräger part number and GTIN quoted above, which is the reference biomedical and procurement teams should carry through to the purchase order so that the correct variant is matched against the installed equipment. Pricing is issued on request rather than listed: submit an RFQ through the enquiry form stating the quantity required, the receiving facility and the devices the item is intended for, and the HumaNova team will respond with a written quotation.

Enquiries covering several part numbers from the same care area can be consolidated into a single request, and related consumables and spares from the Dräger range can be quoted on the same document where a department is replenishing more than one line at a time.

Related cables, sensors & cuffs

3-Lead ECG Lead Set With Snaps (IEC) for Patient Monitoring

3-Lead ECG Lead Set With Snaps (IEC) for Patient Monitoring

PHILIPS
3-Lead ECG Trunk Cable (IEC) for Patient Monitors, Parts & Accessories

3-Lead ECG Trunk Cable (IEC) for Patient Monitors, Parts & Accessories

PHILIPS
3M Bair Hugger Temperature Monitoring Patient Sensors

3M Bair Hugger Temperature Monitoring Patient Sensors

Solventum (3M)
Adult Single Tube Reusable NIBP Cuff, Extra Large

Adult Single Tube Reusable NIBP Cuff, Extra Large

Cables, Sensors & Cuffs
Backplate and Cable for Perfect TCS II

Backplate and Cable for Perfect TCS II

Cables, Sensors & Cuffs
WhatsApp us
Dräger TOF+ Reusable Eyebrow Sensor SW1.8+ | HumaNova